Miscellaneous Drying, Weighing & Grading

    DRYING SAMPLES/ FREEZING AND THAWING STRENGTH

    Book Now Your Machine

    Warm – Air Drier, 220-240 V 50-

    EKE 1415:

    The EKE 1415 Warm – Air Drier is used for drying small amounts of aggregate particles and soil samples. This model have heat and Air flow control option.

    •    Dimensions : 550 x 500 x 200 mm
    •    Weight : 1.5 kg
    •    Power : 2200 W

    Hot – Air Gun, 220-240 V 50-60

    Hot – Air Gun, 220-240 V 50-60 Hz

    EKE 1418:

    The EKE 1418 Hot – Air Gun, is used for drying small amounts of aggregate particles and soil samples. This model have heat and Air flow control option. The EKE 1418 has 300-500°C air temperature and 240-450 L/ min air flow capacity.

    •    Dimensions : 500 x 400 x 200 mm
    •    Weight : 3.5 kg
    •    Power : 1600 W

    Microwave Oven–19 Litter, 220

    Microwave Oven – 19 Litter, 220-240 V 50-60 Hz

    EKE 1420:

    The EKE 1420 Microwave Oven is used for drying , conditioning , moisture determination and pre-heating applications when quick drying is required.

    The EKE 1420 has max. 250°C , 100 min program timer, rotating tray system, 2000 W

    Technical Specifications :
    •    Capacity : 19 Litters
    •    Working Frequency : 2450 Mhz
    •    Internal Dimensions : 210 x 295 x 315 mm
    •    External Dimensions : 450 x 300 x 300 mm
    •    Weight (Approx.) : 11 kg
    •    Power : 2000 W

    Freezing And Thawing Chamber 285L

    Freezing And Thawing Chamber 285 Litter, 220-240 V 50-60 Hz
    Ref. Standard EN 1338, 1339, 1340, 1367-6, 12371, 13748-2; CEN/TS 12390-9

    EKE 1440:

    Used for the determination of resistance to freezing and thawing by providing freezing / thawing in air

    The chamber is equipped with a user defined program including 10 steps. Time can be  adjusted to 999 minutes for each step of the program. The temperature range of the cabinet id -30°C to +30°C

    The temperature is controlled by a sensor which can be immersed either into the sample, into the water which the sample is placed into or, into the salty water solution placed on the sample before starting the test. The calibration of the sensor is carried out using the user friendly menu.

    The cabinet provides maximum 5°C / hour and maximum heating 10°C/hour. The distribution of temperature in the cabinet is performed using the integral fan.

    Software for data transfer to a computer is supplied complete with the cabinet, and data can be monitored during the tests. Data can be converted to an excel report to a graph.

    The condenser of the cabinet is fitted with an air cooled hermetic cooler. The gas used for the cooler does not include CFS’s.

    •    Internal Dimensions : 490 x 530 x 1100 mm
    •    External Dimensions : 690 x 860 x 1940 mm
    •    Weight (Approx.) : 225 kg
    •    Power : 1800 W